Following 4”, 8” and 16” membranes can be used in multiple membrane systems to treat municipal industrial or process water as well as commercial application using the 4” membrane types.
1. Membrane Type |
|
Cross Linked Fully Aromatic Polyamide Composite |
2. Test Conditions |
Feed Water Pressure Feed Water Temperature Feed Water Concentration Recovery Rate Feed Water pH |
110 psi (0.76MPa) 77°F (25°C) 500 mg/l Nacl 15% 7 |
3. Minimum Salt Rejection |
|
99.0% |
4. Minimum Product Flow Rate |
|
2,000gpd (7.6m³/d) (TMG10) 7,500gpd (28.4m³3/d) (TMG20-370) 8,200gpd (31.0m³/d) (TMG20-400) |
Specifications:
Type |
Diameter Inch |
Membrane Area ft2(m2) |
Salt Rejection % |
Product Flow Rate gpd(m3/d) |
Feed Spacer Thickness mil |
TMG10D |
4” |
87(8) |
99.5 |
2,400(9.1) |
31 |
[custom-features]
Standard Operating Limits:
- Maximum Operating Pressure: 365psi (2.5 MPa)
- Maximum Feed Water Temperature: 113°F (45℃)
- Maximum Feed Water SDI15: 5
- Feed Water Chlorine Concentration: Not Detectable
- Feed Water pH Range, Continuous Operation: 2-11
- Feed Water pH Range, Chemical Cleaning: 1-12
- Maximum Pressure Drop per Element: 15 psi (0.10 MPa)
- Maximum Pressure Drop per Vessel: 50 psi (0.34 MPa)
[/custom-features]