1. Membrane Type | Cross Linked Fully Aromatic Polyamide Composite | |
2. Test Conditions | Feed Water Pressure Feed Water Temperature Feed Water Concentration Recovery Rate Feed Water pH | 100 psi (0.69MPa) 77°F (25°C) 500 mg/l Nacl 15% 7 |
3. Minimum Salt Rejection | 99.0% | |
4. Minimum Product Flow Rate | 1,900gpd (7.2m³/d) (TMH10A) 8,800gpd (33.3m³/d) (TMH20A-400) |
[custom-specifications]
Specifications:
Type | DiameterInch | Membrane Area ft² (m²) | Salt Rejection% | Product Flow Rate gpd(m³/d) | Feed Spacer Thickness mil |
TMH20A-400 | 8” | 440 (37) | 99.3 | 11,000(41.6) | 28 |
[/custom-specifications]
[custom-features]
Operating Limits
- Maximum Operating Pressure: 365psi (2.5 MPa)
- Maximum Feed Water Temperature: 113°F (45°C)
- Maximum Feed Water SDI15: 5
- Feed Water Chlorine Concentration: <0.1ppm
- Feed Water pH Range, Continuous Operation: 2-11
- Feed Water pH Range, Chemical Cleaning: 1-12
- Maximum Pressure Drop per Element: 20psi (0.14 MPa)
- Maximum Pressure Drop per Vessel: 60psi (0.4 MPa)
[/custom-features]
[custom-usage]
- Municipal industrial
- Process water
- Commercial applications
[/custom-usage]