Sterilight Platinum SPV
Without UV sterilization, water contaminated with harmful bacteria and viruses requires costly chemical sterilization in order to achieve the highest levels of purity. The Sterilight Platinum is a reliable, economical and chemical-free way to safeguard drinking water in any light commercial application. The Sterilight Platinum has been designed and tested to ensure quality drinking water is at everyone’s finger tips.
The Sterilight Platinum “SPV” series carry the NSF 55, Class A certification. This family has a range of 5 flow rates available from 2.6 to 14.9 USGPM for both POU (point-of-use) & POE (point-of-entry) type applications.
All models deliver a 40 mJ/cm2 UV dose at the system’s alarm set-point. Each system comes equipped with an advanced electronic controller providing a universal power input (100-250V/50-60Hz) & visual display of system performance & lamp life. The Flow Pace™ sensor allows the system to operate with minimal power requirements & heat build-up.
Products | SPV-200 | SPV-410 | SPV-600 | SPV-740 | SPV-950 | |
---|---|---|---|---|---|---|
Flow Rate NSF/EPA 40 mJ/cm² |
9.8 lpm (2.6 gpm) (0.6 m³/Hr) |
22.3 lpm (5.9 gpm) (1.3 m³/Hr) |
32.5 lpm (8.6 gpm) (2.0 m³/Hr) |
42.4 lpm (11.2 gpm) (2.5 m³/Hr) |
56.4 lpm (14.9 gpm) (3.4 m³/Hr) |
|
Dimensions | Length | 45.2 cm (17.8″) |
66.0 cm (26.0″) |
78.0 cm (30.7″) |
100.1 cm (39.4″) |
113.0 cm (44.5″) |
Diameter | 8.9 cm (3.5″) |
8.9 cm (3.5″) |
8.9 cm (3.5″) |
8.9 cm (3.5″) |
8.9 cm (3.5″) |
|
Controller | 25.4 x 11.4 x 5.3 cm (10″ x 4.5″ x 2.1″) |
25.4 x 11.4 x 5.3 cm (10″ x 4.5″ x 2.1″) |
25.4 x 11.4 x 5.3 cm (10″ x 4.5″ x 2.1″) |
25.4 x 11.4 x 5.3 cm (10″ x 4.5″ x 2.1″) |
25.4 x 11.4 x 5.3 cm (10″ x 4.5″ x 2.1″) |
|
Inlet/Outlet Port Size | 1/2″ MNPT | Combo 3/4″ FNPT, 1″ MNPT | Combo 3/4″ FNPT, 1″ MNPT | Combo 3/4″ FNPT, 1″ MNPT | Combo 3/4″ FNPT, 1″ MNPT | |
Shipping Weight | 5.9 kg (13.0 lbs) |
8.2 kg (18.1 lbs) |
9.1 kg (20.1 lbs) |
11.3 kg (24.9 lbs) |
13.6 kg (30.0 lbs) |
|
Electrical | Volts | 100- 250V 50-60Hz |
100- 250V 50-60Hz |
100- 250V 50-60Hz |
100- 250V 50-60Hz |
100- 250V 50-60Hz |
Power Consumption | 35 W | 52 W | 73 W | 88 W | 110 W | |
Lamp Power | 30 W | 45 W | 65 W | 80 W | 100 W | |
Operating Parameters | Maximum Operating Pressure | 8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
Ambient Temperature | 2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
|
Electropolished & Passivated | Yes | Yes | Yes | Yes | Yes | |
Reactor Chamber Material | 316L S.S. | 316L S.S. | 316L S.S. | 316L S.S. | 316L S.S. | |
Communication Port | Yes | Yes | Yes | Yes | Yes | |
Diagnostic Check | Yes | Yes | Yes | Yes | Yes | |
Lamp Replacement Indicator | Yes | Yes | Yes | Yes | Yes | |
Safety Interlock | Yes | Yes | Yes | Yes | Yes | |
Dry Contacts | Yes | Yes | Yes | Yes | Yes | |
Flow Restrictor | Yes | Yes | Yes | Yes | Yes | |
Elapsed Time Meter | Total Hours | Yes | Yes | Yes | Yes | Yes |
Countdown | Yes | Yes | Yes | Yes | Yes | |
Flow Pacing | Yes | Yes | Yes | Yes | Yes | |
UV Intensity Monitor | Yes | Yes | Yes | Yes | Yes | |
NSF/ANSI Standard 55 Class A Validation | Yes | Yes | Yes | Yes | Yes |
Features of the Sterilight Platinum UV purification system
- Validated against the rigours of NSF Standard 55 Class A
- Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye.
- Specially designed and tested Sterilume™-HO lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification.
- The Flow-Pace™ UV Sensor promises system stability and long-life reliability with low power consumption, reducing operating costs and heat transfer into the water.
- Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
- The Sterilight Platinum power supply visually counts down remaining days until lamp replacement, provides total running time of controller, visually represents UV intensity output in % and conducts a full system diagnostic check on start-up.
- Axial Flow reactors include a patented axial flow system installed at the inlet – ensuring water confidence each and every time.
- Residential and commercial applications
-
Love these quality Viqua products
Immensely superior delivery