Cobalt UV
The quality of drinking water can change with time and become contaminated with harmful bacteria. The Sterilight Cobalt™ system is a reliable, economical and chemical-free way to safeguard drinking water in any residential application. The Sterilight Cobalt™ system has been designed and tested to ensure quality drinking water is at everyone’s finger tips.
The Sterilight Cobalt UV disinfection system provides treatment for flow rates up to 40.0 USGPM (151.4 lpm). The Cobalt systems have an electronic controller which comes equipped with a simple LED screen for visual management of the system’s performance and ultimately simple troubleshooting. The controller offers constant current, universal input and full electrical certification. The Sterilight Cobalt PLUS disinfection system provides a UV sensor incorporated into the system for applications of unknown water quality or when a UV monitor is a must.
[custom-specifications]
Products | SC-200 | SC-320 | SC-600 | SC-740 | |
---|---|---|---|---|---|
Flow Rate (95% UVT eol) |
US Public Health (16mJ/cm2) |
56.8 lpm (15.0 gpm) (3.4 m³/Hr) |
94.6 lpm (25.0 gpm) (5.7 m³/Hr) |
227.1 lpm (60.0 gpm) (13.6 m³/Hr) |
227.1 lpm (60.0 gpm) (13.6 m³/Hr) |
R-Can Standard (30mJ/cm²) |
30.3 lpm (8.0 gpm) (1.8 m³/Hr) |
49.2 lpm (13.0 gpm) (3.0 m³/Hr) |
121.1 lpm (32.0 gpm) (7.3 m³/Hr) |
151.4 lpm (40.0 gpm) (9.1 m³/Hr) |
|
NSF/EPA (40mJ/cm²) |
22.7 lpm (6.0 gpm) (1.4 m³/Hr) |
37.8 lpm (10.0 gpm) (2.3 m³/Hr) |
90.8 lpm (24.0 gpm) (5.4 m³/Hr) |
113.6 lpm (30.0 gpm) (6.8 m³/Hr) |
|
Dimensions | Length | 45.2 cm (17.8 “) |
57.9 cm (22.8 “) |
78.0 cm (30.7 “) |
100.1 cm (39.4 “) |
Diameter | 8.9 cm (3.5 “) |
8.9 cm (3.5 “) |
8.9 cm (3.5 “) |
8.9 cm (3.5 “) |
|
Controller | 24.1 x 8.1 x 6.4 cm (9.4″ x 3.2″ x 2.5″) |
24.1 x 8.1 x 6.4 cm (9.4″ x 3.2″ x 2.5″) |
24.1 x 8.1 x 6.4 cm (9.4″ x 3.2″ x 2.5″) |
24.1 x 8.1 x 6.4 cm (9.4″ x 3.2″ x 2.5″) |
|
Inlet/Outlet Port Size | Combo 3/4″ FNPT, 1″ MNPT | 1″ MNPT | 1″ MNPT | 1″ MNPT | |
Shipping Weight | 5.4 kg (11.9 lbs) |
6.8 kg (15.0 lbs) |
8.6 kg (19.0 lbs) |
10.9 kg (24.0 lbs) |
|
Electrical | Volts | 100-240V 50-60Hz |
100-240V 50-60Hz |
100-240V 50-60Hz |
100-240V 50-60Hz |
Power Consumption | 35 W | 42 W | 73 W | 88 W | |
Lamp Power | 30 W | 36 W | 65 W | 80 W | |
Operating Parameters | Maximum Operating Pressure | 8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
8.62 bar (125 PSI) |
Ambient Temperature | 2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
2-40 °C (36-104 °F) |
|
Audible Lamp Failure | Yes | Yes | Yes | Yes | |
Visual “Power On” | Yes | Yes | Yes | Yes | |
Reactor Chamber Material | 304 S.S. | 304 S.S. | 304 S.S. | 304 S.S. | |
Lamp Replacement Indicator | Yes | Yes | Yes | Yes | |
Lamp Type | Sterilume™-HO (high-output) |
Sterilume™-HO (high-output) |
Sterilume™-HO (high-output) |
Sterilume™-HO (high-output) |
|
Visual Lamp Life Remaining | Yes | Yes | Yes | Yes | |
Total Running Time | Yes | Yes | Yes | Yes |
[/custom-specifications]
Features of the Sterilight Cobalt UV Purification System
- Equipped to inactivate chlorine-resistant parasites such as Cryptosporidium and Giardia, harmful bacteria like E.Coli and viruses not visible to the naked eye.
- Specially designed and tested Sterilume™-HO lamps provide consistent and reliable ultraviolet output over the entire life of the lamp (9000 hours) to ensure continuous purification.
- The system is easy to maintain and service.
- The ultraviolet lamp can be changed without interrupting the water flow.
- Built with a durable stainless steel chamber to prolong life and eliminate ultraviolet light degradation.
- The Cobalt™ ICE power supply visually displays the remaining lamp life and will go into alarm if the lamp fails to notify the homeowner.
- The power supply has a sealed case to prevent damage from accidental water intrusion and is fully CSA and CE compliant.
- Light commercial installations and drinking water applications
-
I highly recommend this product.