In comparison with conventional activated sludge treatment, MBR and particularly HYDRAsub ® generate excellent-quality product water acceptable for reverse osmosis processes. HYDRAsub MAX HSMM800-ES Membrane dramatically reduces footprint by removing sedimentation tank and service at greater Mixed Suspended Liquor Solids (MLSS).
[custom-specifications]
HYDRAsub®MAX- MBR | HSMM800-ES | |
Module Specifications |
Configuration: Fiber Orientation: Filtrate Flow: Membrane Polymer: Pore Size (nominal): Number of Elements in Module: Nominal Membrane Area per Module: Permeate Connections: Air Connections: Guide Pipe Connections: Typical Module Dry Weight: Typical Module Wet Weight: |
Submerged Membrane Vertical Bi-directional Polyvinylidene Flouride (PVDF) 0.05 μm 20 (40 m² each) 8608 ft2 (800 m²) (2)- 2” MNPT Connections (2)- 2” MNPT Connections (2)- To fit 3” pipes 1197 lbs (544 kg) 1880 lbs (853 kg) |
Typical Process Conditions |
Operating Filtrate Flux†: Peak Operating Flux†: Chemically Enhanced Backwash (CEB) Flux: CEB Chemicals: Clean In Place (CIP) Flux: CIP Chemicals: |
4-20 gfd (7-34 lmh) 30 gfd (51 lmh) 2.4 gfd (4 lmh) NaOCld 2.4 gfd (4 lmh) NaOCl or Citric Acidd |
[/custom-specifications]
[custom-features]
Features
- Maximum Trans Membrane Pressure (Vacuum): -6 psig (-0.41 bar)
- Maximum Backwash Trans Membrane Pressure: 2 psig (0.14 bar)
- Maximum Instantaneous Chlorine Concentration: 5,000 ppma
- Maximum Chlorine Tolerance: 742,000 ppm-hrsb
- MLSS Range: 8,000 - 12,000 mg/Lc
- Operating Temperature Range: 41 - 104°F (5 - 40° C)
- Feed Water pH Range: 6.0 - 8.0
- Cleaning pH Range: 1.0 - 11.0
- Operating Mode: Outside to Inside